RETIRED ›
This product is no longer available and has been replaced by: CR300,CR310. Some accessories, replacement parts, or services may still be available.
CR200X Datalogger
Our Smallest,
Lowest-Cost Datalogger

weather applications supported water applications supported energy applications supported gas flux & turbulence applications supported infrastructure applications supported soil applications supported

Overview

The CR200X, our smallest lowest-cost datalogger, provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits the data using communication peripherals. CRBasic, its full programming language, supports simple or complex programming. Multiple CR200Xs can be configured as a network, or units can be deployed individually.

Read More

Benefits and Features

  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
  • Campbell Scientific’s smallest, lowest cost datalogger
  • Gas Discharge Tube (GDT) protected inputs
  • Optimal for measuring one or two simple sensors
  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
  • Battery-backed clock that ensures accurate time is maintained while datalogger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup
  • PakBus, Modbus, and SDI-12 protocols supported

Images

Detailed Description

The CR200X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR200X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples (refer to the Compatibility information for compatible sensors, peripherals, and software). Recalibration services are not offered for the CR200X datalogger.

Specifications

-NOTE- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
Maximum Scan Rate 1 Hz
Analog Channels
  • The single-ended analog inputs can also be used as control ports.
  • 5 single-ended (no differential) individually configured
Pulse Count Channels 2
Switched Excitation Channels 2 voltage
Digital Ports
  • Certain digital ports can be used to count switch closures.
  • 2 I/O
Communication Ports 1 RS-232
Switched Battery Port 1
Input Voltage Range 0 to 2500 mV
Analog Voltage Accuracy ±(0.25% of reading + (1.2 mV)x(offset)) at -40° to +50°C
Analog Voltage Resolution 0.6 mV
A/D Bits 12
Operating Temperature -40° to +50°C
Power Requirements 7 to 16 Vdc
Typical Current Drain
  • ~0.2 mA (quiescent)
  • ~3 mA (active)
Protocols Supported PakBus (leaf node only), SDI-12
CE Compliance Standards to which Conformity Is Declared IEC61326:2002
Warranty 3 years
Dimensions 14.0 x 7.6 x 4.8 cm (5.5 x 3.0 x 1.9 in.)
Weight 242 g (8.5 oz)

Memory

Final Storage 512 kB of flash memory for approximately 125,000 data points
Operating System 106 kB of flash memory
Intermediate Storage 8 kB of SRAM for communication buffers, calculations, variables, etc.

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Measurement and Control

Compatible Note
AM16/32B
AM25T

Software

Compatible Note
LOGGERNET Version 2.1 or higher
PC200W
PC400 Version 1.0 or higher
PCONNECT (retired) Version 3.0 or higher
PCONNECTCE (retired) Version 2.0 or higher
Short Cut
VISUALWEATHER Version 2 or higher

Additional Compatibility Information

Communications

The CR200X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.

Measurement & Control Peripherals

The CR200X is not compatible with SDM devices and multiplexers.

Sensors

The CR200X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the datalogger and the pn 16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the pn 16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR200X-based systems.

Power Supplies

The CR200X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the datalogger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

Downloads

CR200X Series OS v.04 (1.29 MB) 22-09-2015

Execution of this download installs the Operating System and Compiler on your computer for the following dataloggers:CR200X, CR206X, CR211X, CR216X and CR295X.  It also updates the support files for the CRBasic Editor.  

Note: Newer CR206X dataloggers (serial # ≥ 19122) and newer CR211X dataloggers (serial # ≥ 19143) have 250 mW radios that must use OS 3 or higher for their datalogger operating system.

View Revision History