CR9000X Datalogger Base System
Fastest Datalogger
Customizable, ideal for demanding research applications
weather applications supported water applications supported energy applications supported gas flux & turbulence applications supported infrastructure applications supported soil applications supported

Overview

The CR9000X is a large, modular multiprocessor system that provides precision measurement capabilities in a rugged, battery-operated package. It consists of a base system and a chassis with slots for up to nine user-selected I/O modules. The CR9000X is our fastest datalogger, with a measurement rate of 100,000 Hz, making it ideal for rapid sampling applications.

For the entire list of available I/O modules for the CR9000X and CR9000XC, visit the CR9000X-Series I/O Modules page.

Campbell Scientific also offers the CR9000XC, a compact version, that accepts up to five I/O modules.

Read More

Benefits and Features

  • Up to nine I/O modules can be used to configure a system for your specific application
  • Ideal for vehicle testing, structural or seismic monitoring, or other applications that require rapid sampling or a large number of high resolution channels
  • Throughput of 100,000 measurements per second is ideal for high demand research, such as flux and complex structural monitoring
  • Contains an on-board 10baseT/100baseT port allowing direct Ethernet connection; an interface such as the NL100 is not required
  • CR9052IEPE and CR9052DC modules provide powerful anti-aliasing and real-time FFT capabilities that are unique to the CR9000X-series dataloggers
  • Integrated PCMCIA slot accepts memory cards up to 2 GB for stand-alone data collecting
  • Gas Discharge Tube (GDT) protected inputs
  • Collects and stores data and controls peripherals as the brain of your system

Images


Specifications

-NOTE-
  • Additional specifications are listed in the CR9000X(C) Specifications Sheet.
  • For the CR9000X, the current drain, weights, and specific number of input/output channels depend on the I/O modules chosen.
Operating Temperature Range
  • -25° to +50°C (standard)
  • -40° to +70°C (extended)
  • Non-condensing environment
Analog Inputs 28 single-ended or 14 differential per CR9050, CR9051E, or CR9055(E) module
Pulse Counters 12 per CR9071 module
Communications Ports
  • CS I/O
  • RS-232
  • 10baseT/100baseT
Switched 12 Volt 1 terminal
Digital I/O
  • Certain digital ports can be used to count switch closures.
  • 1 SDM and 8 outputs per CR9060 module or 16 I/Os per CR9071 module
Analog Voltage Accuracy ±(0.07% of reading + 4 A/D counts), -25° to +50°C
ADC 16-bit
Power Requirements 9.6 to 16 Vdc
Communication Protocols SDM
Warranty 3 years
Dimensions
  • 40.1 x 24.9 x 20.3 cm (15.8 x 9.8 x 8 in.) for lab enclosure
  • 45.7 x 34.9 x 22.9 cm (18 x 13.5 x 9 in.) for field enclosure
Weight
  • 13.6 kg (30 lb) with modules in lab enclosure
  • 19.1 kg (42 lb) with modules in field enclosure

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Software

Compatible Note
LOGGERNET Version 2.0 or higher
PC200W
PC400 Version 1.0 or higher
RTDAQ Version 1.0 or higher
Short Cut
VISUALWEATHER Version 2.0 or higher

Additional Compatibility Information

Compatibility with Retired Products

Customers can add CR9000X dataloggers to networks containing the older CR9000 or CR9000C dataloggers. I/O modules other than the CR9080 can be used with either the CR9000 or CR9000X. CR9000 communication interfaces (i.e., NL105, BLC100, TL925, PLA100) are not compatible with the CR9000X, and therefore have been retired.

Sensors

With several channel types, the CR9000X is compatible with many sensors, including thermocouples and 4 to 20 mA sensors.

Measurement and Control Peripherals

Measurement and control peripherals typically used with the CR9000X are our AM25T 25-Channel Solid State Multiplexer, SDM-CAN Interface, SDM-INT8 Eight Channel Interval Timer, and SDM-SIO4 Serial Input/Output Module. Other measurement and control peripherals are compatible but they do not support the CR9000X datalogger's maximum measurement rate and are therefore impractical for most CR9000X applications.

Communications

The CR9000X typically communicates with a PC via direct connect or Ethernet. Because the CR9000X has an on-board 10baseT/100baseT port, an Ethernet interface such as the NL201 is not required. 

Storage capacity can be increased by using a PC or CompactFlash card. The CR9000X's PCMCIA card slot supports one Type I, Type II, or Type III PC Card or the CF1 adapter and one CompactFlash (CF) card.

The storage capacity of Type II cards exceeds 1 GB. Type III cards provide data storage capacities exceeding 1 GB but may not be suitable for all environments. Campbell Scientific offers several CF cards that have passed our ESD testing and operate properly with our data loggers (see Ordering tab). Please note that the PCMCIA and CompactFlash cards need to be industrial-grade and have a storage capacity of 2 GB or less.

Other communication peripherals are compatible but they do not support the CR9000X datalogger's maximum measurement rate and are therefore impractical for most CR9000X applications.

Enclosures

Two enclosures are offered for the CR9000X. The 8253 fiberglass environmental enclosure is designed for field applications where the enclosure will be exposed to the elements. The 8255 lab enclosure is for applications where the CR9000X will reside inside a building.

Software

CRBasic, the CR9000X's full programming language, supports simple or complex programming and many on-board data reduction processes. CRBasic is included in RTDAQ, LoggerNet, and PC400.

RTDAQ Real-Time Data Acquisition Software must be ordered separately; the CR9000X is also compatible with other Campbell Scientific software.

Downloads

CR9000X OS v.6 (4.04 MB) 23-01-2012

Current Operating System, Compiler and CR9000X support files for the CRBasic Editor. Requires the Device Configuration Utility, LoggerNet or RTDAQ to upload.

Use of this file will update the datalogger support files for the CRBasic Editor included in LoggerNet and RTDAQ.

View Revision History

PC9000 Patch v.5.3.1 (21.9 MB) 02-03-2007

RETIRED PRODUCT

Upgrade PC9000 version 5.0, 5.1, 5.2 or 5.3 to 5.3.1; no intermediate steps are required.

PC9000 5.0, 5.1, 5.2 or 5.3 must be installed on your machine.

View Revision History

Articles and Press Releases

FAQs for

Number of FAQs related to CR9000X: 46

Expand AllCollapse All

  1. The CR9000X and CR9000XC differ only in the number of I/O cards they can hold. The CR9000X can hold 9 I/O cards, and the CR9000XC can hold 5 I/O cards. We provide both sizes to accommodate our customers; the same I/O cards can be used in either chassis.

  2. There are two ways to upgrade an operating system:

    Method 1

    1. Connect to the CR9000X using the serial link or the Ethernet link.
    2. Use the RTDAQ | Clock/Program Tab | Send Program… button.
    3. In the Files Type box in the file browser window, use the drop-down arrow to select OBJ Files (*.obj). Browse to the computer file where the desired operating system resides.
    4. Double-click the file, or click the Open button. A warning will appear.
    5. After reading the warning, click Yes to begin downloading the new operating system.

    Method 2

    1. Download and install the Device Configuration Utility software, or launch it from RTDAQ.
    2. Connect the CR9000X RS-232 port to the computer.
    3. Select CR9000X from the list in the Device Configuration Utility.
    4. Select the Send OS tab, and follow the instructions displayed in the software interface screen.
  3. The CR3000 program will have to be modified so that each measurement or control instruction includes the appropriate module number. Some parameters might differ as well.
  4. The advantage of the BrHalf4W circuit is that the effect of lead resistance is measured and compensated for. The disadvantage is that it requires two differential (four single-ended) voltage input channels and four wires to the sensor.

    Some sensors have four wires and are sensitive enough that the lead resistance would cause too great an error.

    The BrHalf, a two-wire measurement, does not compensate for lead resistance.

    The BrHalf3W lead compensation assumes that both leads are of the same resistance.

  5. Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such as TimeIntoInterval(). Another option is to use an IfThen/EndIf construction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination of RealTime() and Case instructions.

    For more information, see the “Decisions, Decisions, Decisions…” article. 

  6. All the input terminals, peripheral and communications terminals, operating system, and Flash EEPROM are checked. The data logger is checked to ensure that all hardware operates within published specifications.

  7. Use the full-bridge instruction, BrFull(). An example program for the CR1000 can be found in the “Datalogger Programming” section of the “ST350 Strain Transducer Instruction Manual.”

  8. The maximum cable length depends on the interface being used.

    • RS-232 connections will reach 15 m (50 ft).
    • RS-485 connections go beyond 610 m (2,000 ft).
    • IP connections can be routed worldwide.