CPEC310
 
CPEC310 Expandable Closed Path Eddy Covariance System w/EC155, Pump Module, & 3-Valve Module
 
Datalogger Option
-DW -DW Wired for CR6
-6NA -6NA w/CR6-NA
-WIFI -WIFI w/CR6-WIFI
-RF451 -RF451 w/CR6-RF451
VOLT116 Option
-NAM -NAM w/o VOLT116
-AM -AM w/VOLT116
Keyboard Option
-NK -NK No Keyboard/Display
-KD -KD w/Keyboard/Display
Sonic Sensor Option
-NS -NS No Sonic Sensor
-SS1 -SS1 w/CSAT3A, Std
-SS2 -SS2 w/CSAT3A, Harsh
-SS1 Sonic Carrying Case Opt - show details
-NC -NC No Sonic Case
-SC -SC Sonic Carrying Case
It is recommended to purchase a carrying case to protect the sensor
-SS2 Sonic Carrying Case Opt - show details
-NC -NC No Sonic Case
-SC -SC Sonic Carrying Case
It is recommended to purchase a carrying case to protect the sensor
EC155 Carrying Case Opt - show details
-NG -NG No EC155 Case
-GC -GC EC155 Carrying Case
It is recommended to purchase a carrying case to protect the sensor
System Mounting Options
-NM -NM No Enclosure Mounting
-MM -MM Tripod Mast Mounting
-LM -LM CM106 Leg Mounting
-TM -TM Tower Mounting
-PM -PM Pole Mounting, 4-10in

Add to your Quote List


Common Accessories

L27158
 
Campbell Scientific recommends using at least one microSD card with the system, and the 27158 is one option. The 27158 is a 2 GB microSD flash-memory card designed for use in harsh conditions often presented by environmental and industrial applications.
38476
 
Campbell Scientific recommends using at least one microSD card with the system, and the 38476 is one option. The 38476 is a 16 GB microSD flash-memory card designed for use in harsh conditions often presented by environmental and industrial applications in which customers require higher reliability, endurance, and performance but also seek a cost-effective solution to meet budget-planning requirements.
L17752
 
The 17752 is a multiple-slot, high-speed reader/writer that allows a computer to read a memory card. When used with Campbell Scientific equipment, the 17752 typically reads data stored on CompactFlash or microSD cards, but it can read many different types of memory cards. The 17752 connects to the computer's USB port.

Other Accessories

EASYFLUXWEBH
 
EASYFLUXWEBH EasyFlux Web Software CSI-Hosted One-Time Implementation Fee
 
EasyFlux™ Web CSI-Hosted is a web-based software tool for monitoring CR6- and CR3000-based Campbell Scientific, Inc., eddy-covariance systems. EasyFlux™ Web CSI-Hosted is hosted on Campbell Scientific's own Microsoft Azure server, which allows for automatic updates and maintenance of the software. After users create an account, they are given their own IP address to allow them to easily connect to their data from an Internet-connected device. Monitoring a network of eddy-covariance systems is made easy with real-time data monitoring, customizable alerts, and data download capabilities. EasyFlux™ Web is compatible with open- and closed-path eddy-covariance systems.
EASYFLUXPC
 
EasyFlux™ PC is a free computer program that processes high frequency time series data, collected using a Campbell Scientific eddy-covariance flux system, into fluxes following community accepted practices. Fully corrected fluxes of CO2, latent heat (H2O), sensible heat, and momentum are available, in generic, AmeriFlux, and GHG-Europe ASCII formats.
EASYFLUXDL
 
EasyFlux™ DL is a free CRBasic program that enables a datalogger to report fully corrected fluxes of CO2, latent heat (H2O), sensible heat, and momentum from a Campbell Scientific open-path eddy-covariance (EC) system. Final fluxes are processed from raw high frequency time series data by applying commonly used corrections found in scientific literature.
EOSFD
 
The eosFD uses the patented Forced Diffusion (FD) technology to measure soil CO2 flux directly using an NDIR sensor and small internal diaphragm pump. It features onboard data logging capabilities that enable it to be a stand-alone sensor; however, it can also deliver analog or serial data to Campbell Scientific data loggers. This sensor compliments a Campbell Scientific eddy-covariance system. The included eosLink software enables you to connect, configure, and collect data directly from the sensor.

Replacement Parts

4905
 
The 4905 is replacement desiccant for the enclosures in this system.
27555
 
The 27555 is a USB Type A to Micro B, male-to-male cable, 6 to 6.5 ft long. It connects devices using the Micro B interface to a USB port on a computer.
L32203
 
The 32203 is a replacement in-line filter kit for the EC155 heated vortex. The kit includes a 25 µm filter and new ¼ in. Swagelok® nuts.
L560
 
The 560 screw is used to attach a backplate to the inside of an enclosure.
26559
 
The CM250 is a leveling mount kit for attaching the EC155 to a crossarm.
L16005
 
Note: This replacement part is only applicable to the -WIFI option.

The 16005 is a unity gain (0 dBd), 1/2 wave whip, omnidrectional antenna that features an articulating knuckle joint for easy orientation, weatherized jacket for outdoor applications, and internal counterpoise for ground plane independence.

Services

 
The 27332 provides a recalibration with zero and span. When drift between zero and span checks seems unstable, or when diagnostic output indicates a problem, the instrument should be sent in for a full factory calibration with zero and span. An RMA is required.
 
The 27333 allows customers to send their EC155 or CPEC310 to Campbell Scientific and have Campbell Scientific perform a zero and span; an RMA (Returned Material Authorization) is required. The zero and span should be done when ambient conditions change significantly (i.e., seasonally).