DS5X Hydrolab DataSonde® 5X Multiprobe
Low maintenance
Includes Central Cleaning Unit
weather applications supported water applications supported energy applications supported gas flux & turbulence applications supported infrastructure applications supported soil applications supported

Overview

The DataSonde 5X offers Hydrolab's Superior Sensor Technology with a self-contained, automatic cleaning system for maximum deployment life with minimum maintenance.

Ideal for “X-tended” deployments in environments where fouling and sediment are abundant

Read More

Images

Specifications

Size:

  • Outer diameter - 3.5 in/8.9 cm
  • Length - 23 in/58.4 cm
  • Weight: 7.4 lbs/3.35 kg (typical)

General:

  • Computer Interface: RS-232, SDI-12, RS-485
  • Memory: 120,000 measurements
  • Battery Supply: 8 C batteries
  • Operating Temperature: -5 to 50° C
  • Maximum Depth: 225 m

Sensors Parameter (Range, Accuracy, Resolution):

  • Hach LDO: 0 to 60 mg/L ±0.1 mg/L @ < 8mg/L ±0.2 mg/L @ > 8mg/L 0.01mg/L
  • Polarographic DO: 0 to 50 mg/L ±0.2 mg/L @ < 20mg/L ±0.6 mg/L @ > 20mg/L 0.01mg/L
  • Conductivity: 0 to 100 mS/cm ±0.5% of reading; ±0.001 mS/cm 4 digits pH 0 to 14 units ±0.2 units 0.01 units
  • Turbidity, Self-Cleaning: 0 to 3000 NTU Compared to StablCal 1% up to 100 NTU 3% from 100-400 NTU 5% from 400-3000 NTU 0.1 NTU from 0-400 NTU 1 NTU for >400 NTU
  • Turbidity, 4-Beam: 0 to 1000 NTU 5% of reading; or ± 1 NTU 0.1 NTU from 0-100 NTU 1 NTU >100 NTU
  • Depth: 0 to 10m (Vented Level) ±0.003m 0.001m 0 to 25m ±0.05m 0.01m 0 to 100m ±0.05m 0.01m 0 to 200m ±0.1m 0.1m
  • Chlorophyll a (Dynamic Range): 
    • Low sensitivity: 0.03 to 500 µg/L
    • Med. sensitivity: 0.03 to 50 µg/L
    • High sensitivity: 0.03 to 5 µg/L ±3% for signal levels equivalens of 1 ppb rhodamine WT dye or higher using a rhodamine sensor 0.01µg/L
  • Blue-Green Algae (Dynamic Range)
    • Low sensitivity: 100 to 2,000,000 cells/mL
    • Med. sensitivity: 100 to 200,000 cells/L
    • High sensitivity: 100 to 20,000 cellsL ±3% for signal levels equivalens of 1 ppb rhodamine WT dye or higher using a rhodamine sensor 20 cells/L
  • Ion Selective Electrodes
  1. Ammonia Max Depth: 15 meters 0 to 100 mg/L-N Greater of ±5% of reading or ±2 mg/L-N 0.01 mg/L-N
  2. Nitrate Max Depth: 15 meters 0 to 100 mg/L-N Greater of ±5% of reading or ±2 mg/L-N 0.01 mg/L-N
  3. Chloride Max Depth: 15 meters 0.5 to 18,000 mg/L greater of ±5% of reading or ±2 mg/L 4 digits
  • TGO (Total Dissolved Gas): 400 to 1300 mmHg ±0.1% of span 1.0 mmHg
  • ORP: -999 to 999 mV ±20mV 1mV
  • Rhodamine WT (Dynamic Range)
    • Low sensitivity: 0.04 - 1000 ppb
    • Med. sensitivity: 0.04 - 100 ppb
    • High sensitivity: 0.04 - 10 ppb ±3% for signal levels equivalens of 1 ppb rhodamine WT dye or higher using a rhodamine sensor 0.01 ppb
  • PAR: 0 to 10,000 µmols-1m-2 ±5% of reading or ±1µmol s-1m-2 1µmol s-1m-2
  • Temperature: -5° to 50°C ±0.10°C 0.01°C

Compatibility

Datalogger Considerations

Compatible Contemporary Dataloggers

CR200(X) Series CR800/CR850 CR1000 CR3000 CR5000 CR7X CR9000X

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR9000