Product Information - HMP45CF (Discontinued)

Print this page

Relative Humidity (0-100%) and 107F Air Temperature Probe (-55° to +50°C) (41003-2 Radiation Shield required)

Click picture for full size image.
Model Cable Length
HMP45CF 10 Ft
HMP45CF-L Custom

Manual, Version Date: May, 1999  Manual

General Description

The HMP45CF Temperature and Relative Humidity probe contains Betatherm 0.3K1A1A thermistor thermistor and a Vaisala HUMICAP® 180 capacitive relative humidity sensor.

Specifications

Operating Temperature: -55°C to +50°C
Probe Length: 25.4 cm (10 in.)
Probe Body Diameter: 2.5 cm (1 in.)
Filter: 0.2 µm Teflon membrane
Filter Diameter: 1.9 cm (0.75 in.)
Power Consumption: <4 mA
Supply Voltage (via CSI switching circuit): 7 to 35 VDC
Settling Time: 0.15 seconds

Temperature Sensor
Sensor: Betatherm 0.3K1A1A Thermistor
Temperature Measurement Range: -55°C to +50°C
Temperature Interchangeability Error: <±0.2°C
Accuracy:
-50°C to -40°C: ±1.0°C
-40°C to -30°C: ±0.8°C
-30°C to +50°C: ±0.6°C
-10°C to +10°C: ±0.3°C
107F Accuracy
Relative Humidity Sensor
Sensor: HUMICAP® 180
Relative Humidity Measurement Range: 0 to 100% non-condensing
RH Output Signal Range: 0.008 to 1 VDC
Accuracy at 20°C ±2% RH (0 to 90% Relative Humidity)
±3% RH (90 to 100% Relative Humidity)
Temperature Dependence of Relative Humidity Measurement: ±0.05% RH/°C
Typical Long Term Stability: Better than 1% RH per year
Response Time (at 20°C, 90% response): 15 seconds with membrane filter

Note: The black outer jacket of the cable is Santoprene® rubber. This compound was chosen for its resistance to temperature extremes, moisture, and UV degradation. However, this jacket will support combustion in air. It is rated as slow burning when tested according to U.L. 94 H.B. and will pass FMVSS302. Local fire codes may preclude its use inside buildings.

Download Adobe Acrobat Reader



Home | What's New | Products | Services | Applications | Courses & Shows | Museum | Literature | Privacy | About Us
Contact Us | Recruitment | Search | Links | Conversions | Download | Site Map

Questions? Please refer to the email address in this graphic if the adjacent link does not work.   Phone: (780) 454 2505
© 2001 Campbell Scientific (Canada) Corp.  