Product Information - COM200 (Discontinued)

Print this page

Replacement Product - COM210

Telephone Modem (9600 Baud; includes SC12 Cable)

Click picture for full size image.
Model Temperature Range
COM200 -25 to +50°C
COM200 -XT -40° to +50°C

Manual, Version Date: September 28, 2001  Manual

General Description

The COM200 Modem enables communication between a computer and a Campbell Scientific datalogger (CR510, CR500, CR10(X), 21X, CR23X, CR5000, or CR7) over a public switched telephone network. A Hayes-compatible modem is required at the computer; the COM200 is connected to the datalogger. The COM200's wide operating temperature range and low power requirements optimize it for use in remote applications.

Specifications

  • Bell 212A, CCITT V.22, and CCITT V.32 compatible
  • Full duplex at 9600 and 1200 baud to datalogger
  • V.42 LAPM and MNP2-4 error correction
  • Hayes AT command set
  • RJ-11C telephone jack
  • FCC and IC (formally known as DOC) approval
  • Pulse or tone dialing
  • Current drain: 120 µA quiescent, 140 mA active
  • Direct connection to and powered by Campbell Scientific dataloggers
  • Supply requirements: 12 VDC regulated power supply
  • Internally switches 12 VDC external power minimizing current drain
  • Logic levels: below 1.5 V inputs a low state and above 3.5 V inputs a high state. A low voltage level on the TX data input (pin 9) and RX data output (pin 4) represents a mark
  • Size: 5.2 x 1.7 x 3.6 in // 13.1 x 4.3 x 9.2 cm
  • Weight: 0.75 lbs // 0.34 kg