Product Information - CH512R (Discontinued)

Print this page

Replacement Product - CH100 with A100

12 Volt Charger/Regulator and 5 Volt Power Supply (AC adapter not included)

Click picture for full size image.

Features

  • Used to connect rechargeable batteries with a charging source, such as ac power or unregulated solar panels

General Description

The CH512R charging regulator is used with a Campbell Scientific battery pack or with a user-supplied battery. Charging power is typically supplied by a CSC Model L9591 AC Transformer or by a solar panel (MSX10, MSX20 or MSX30R).

The CH512R has two 9-pin connectors that provide a null modem for use in a site, without a datalogger, that connects and powers two Campbell Scientific peripherals that would normally be connected to a datalogger. These peripherals are typically modems linking different communications technologies (e.g., telephone to radio).

Specifications

Input Voltage (CHG terminals): 15 to 28 VDC or 18 VAC RMS
Battery Connections
Charging Output Voltage: Temperature compensated float charge for 12 V Battery
Temperature Compensation Range: -40° to +60°C
Charging Current Limit: 1.2 Amps typical
Power Out (+12 terminals)
Voltage: Unregulated 12 V from Battery
Current Limited with 3A Thermal Fuse: > 3 A @ < 20°C
3 A @ 20°C
2.1A @ 50°C
1.8 A @ 60°C
Download Adobe Acrobat Reader



Home | What's New | Products | Services | Applications | Courses & Shows | Museum | Literature | Privacy | About Us
Contact Us | Recruitment | Search | Links | Conversions | Download | Site Map

Questions? Please refer to the email address in this graphic if the adjacent link does not work.   Phone: (780) 454 2505
© 2001 Campbell Scientific (Canada) Corp.