Product Information - CH12R (Discontinued)

Print this page

Replacement Product - CH100

12 Volt Charger/Regulator (AC adapter not included)

Click picture for full size image.
Brochure, Version Date: February, 2011  Brochure

Features

  • Used to connect rechargeable batteries with a charging source, such as ac power or unregulated solar panels

General Description

The CH12R charging regulator is used with a Campbell Scientific battery pack or with a user-supplied battery. Charging power is typically supplied by a CSC Model L9591 AC Transformer or by a solar panel (MSX10, MSX20 or MSX30R).

Specifications

Input Voltage (CHG terminals): 15 to 28 VDC or 18 VAC RMS
Battery Connections
Charging Output Voltage: Temperature compensated float charge for 12 V Battery
Temperature Compensation Range: -40° to +60°C
Charging Current Limit: 1.2 Amps typical
Power Out (+12 terminals)
Voltage: Unregulated 12 V from Battery
Current Limited with 3A Thermal Fuse: > 3 A @ < 20°C
3 A @ 20°C
2.1A @ 50°C
1.8 A @ 60°C