Product Information - 41342

Print this page

RM Young Platinum Temperature Probe

Click picture for full size image.
Model Cable Length Output
41342 None 4 wire RTD
41342-L Custom 4 wire RTD
 
41342LC None 4-20 mA
41342LC-L Custom 4-20 mA
 
41342VC None 0-1 VDC
41342VC-L Custom 0-1 VDC

Brochure, Version Date: September, 2001  Brochure


General Description

The Model 41342 RM Young Platinum Temperature Probe offers accurate temperature-only measurement. Three output options are available: 4 wire RTD, 0-1 VDC (V Option), and 4-20 mA (L Option). Probes are easily installed in RM Young naturally ventilated (multi-plate) and aspirated radiation shields. A junction box is provided for cable terminations. Includes the R41046DS-24 adapter plug.

Specifications

Power Required:
V Option:
5 mA, 8-24 VDC
L Option: 20 mA, 12-30 VDC
Temperature:
Calibrated Measuring Range: -50 to 50°C
Time Constant: 42 seconds with Model 43408 Aspirated Radiation Shield
Accuracy at 0°C: ±0.3°C **
±0.1°C (optional) with NIST traceable calibration
Sensor Type: 1000 Ohm Platinum RTD
Output Signal: 4 wire RTD (41342 only)
V Option: 0-1 VDC
L Option:4-20 mA
Recommended Radiation Shields: Model 41003-X Gill Multi-Plate Radiation Shield Model 43502 Gill Aspirated Radiation Shield

** Differential measurement recommended with V option.

Download Adobe Acrobat Reader



Home | What's New | Products | Services | Applications | Courses & Shows | Museum | Literature | Privacy | About Us
Contact Us | Recruitment | Search | Links | Conversions | Download | Site Map

Questions? Please refer to the email address in this graphic if the adjacent link does not work.   Phone: (780) 454 2505
© 2001 R.M. Young Company, 2002 Campbell Scientific (Canada) Corp.