Product Information - 223

Print this page

Soil Moisture Block without Blocking Capacitors (for Multiplexer)

Click picture for full size image.
Model Cable Length
223 50 Ft
223-L 50 Ft Base Lead + Custom

Manual, Version Date: August, 1999  Manual

Features

  • Uses electrical resistance method for soil water matric potential measurement
  • Measurement range: -1000 kPa to -10 kPa
  • Used when multiplexers are connected between the datalogger and the sensor
  • Manufactured by Delmhorst

General Description

The 223 estimates soil water potential from 0.1 to 10 bars. It is identical to the 227 but configured for use with an AM16/32 multiplexer.

When the 223 is wet, electrical resistance is low. As the 223 dries, resistance increases. Calibration of individual probes is recommended for accurate soil water potential measurements. We recommend that probes be removed during winter. Expected life is two freeze-thaw cycles.

Download Adobe Acrobat Reader



Home | What's New | Products | Services | Applications | Courses & Shows | Museum | Literature | Privacy | About Us
Contact Us | Recruitment | Search | Links | Conversions | Download | Site Map

Questions? Please refer to the email address in this graphic if the adjacent link does not work.   Phone: (780) 454 2505